Research & Technical Library

Materials & finishing

Catalyst conditions and selective plating on two-shot injection molded parts

Overview

We varied catalyst conditions for two-shot injection molded parts and compared coverage in the intended areas with unwanted plating.

To evaluate selective plating on two-shot injection molded parts, we tested different catalyst concentrations and immersion times. We checked both coverage in the intended plating areas and deposition on areas that should remain unplated.

The comparison conditions for the standard two-shot molded specimens received passing quality results. Separate specimens with a special geometry showed both unplated areas and unwanted plating.

AttachmentCatalyst conditions and selective plating on two-shot injection molded parts.docx
Back to list

Notice

You do not have permission to download this file.