Overview
We compared aqueous pre-etch temperatures and treatment times to examine the balance between surface damage and plating adhesion.
During development of an aqueous pre-etch for PC-Si, we compared bath condition, treatment temperature, and treatment time. Appearance and delamination were checked for each condition, with sequential repeat trials in the same bath.
Some conditions reduced surface damage and produced specimens with favorable on-site adhesion test results. Delamination, surface damage, and phase separation in the mixed bath under other conditions were also recorded.