Overview
We compared conditions for reducing unplated areas and bubbles on PC-Si, then checked adhesion after subsequent metal layers were added.
We compared existing pretreatment and plating conditions to reduce unplated areas and bubbles on PC-Si. Changes associated with surface conditioning, drying, and subsequent metal layers were assessed through same-day and later adhesion tests.
Some conditions improved coverage and next-day adhesion, but specimens with additional metal layers showed delamination. Testing of that pretreatment route was concluded, and work moved on to developing an alternative pretreatment.